PDF for

Overview

This RFID temperature tag provides highly accurate, real-time data collection without human intervention in wireless applications such as identification, tracking, cold chain, localization of high value assets and temperature monitoring.

This temperature tag transmits and receives data at distances of up to 250 m (800 feet). It can also be easily configured to beacon data at a range of up to 500m (1600 ft). The long range tag contains an internal temperature monitoring sensor in order to measure and log the temperature of goods in definable intervals. It is also available with external sensors. Using an integrated LED, the sensor provides visual recognition. This tag is able to store user and process information as well as temperature data to provide real-time tracking.

Key Features

  • Beacon communication mode
  • Response communication mode
  • Spot location for gate applications
  • 10,000 Bytes memory
  • 2000-sensor simultaneous identification
  • Temperature logging
  • Non-line-of-sight data transmission
  • LED
  • Localization of high value assets

Applications

  • Identification
  • Cold chain
  • Localization of high value assets
  • Temperature monitoring

Technical Specifications


Communication Broadcast
Operation ModeTransmits Sensor ID and user data in pre-defined interval
Read Rangeup to 500m (1600ft)*
Compatibility227002, 227003, 227004
Operating Frequency868 MHz (EU) or 920 MHz (NA
Transmit Power<1mW
Communication Response
Operation ModeBi-directional communication (reading log, blink LED, write/read data)
Read Rangeup to 250m (800ft)*
Compatibility227002, 227003, 227004
Operating Frequency868 MHz (EU) or 920 MHz (NA)
Transmit Power<1mW
Communication Marker
Operation ModeReceives Marker ID and transmits marker information several times via Broadcast 350 telegrams
Read Rangeup to 5 m (16ft)*
Compatibility491013,491014
Operating Frequency125 kHz
Temperature Sensor
Number of logging samples10.000
Logging Intervaluser definable in intervals from 1 to 255 min
Measuring Intervaluser definable in intervals from 0 seconds to 255 min
Metering Range-40C to +85C (-40F to +176F) with integrated sensor
-80C to +100C (-112F to +212F) with external sensor
Resolution0.1 C (0.2 F)
Accuracy+- 0.5 C (1 F) from -20 C up to +50 C (68 F up to 122F)
+- 1.0 C (2 F) in the remaining temperature range
Environmental Conditions
Operating Temperature40 C to +85 C (40 F to +185 F)
ShockMultiple drops to concrete from 1m (3ft), 3 times DIN IEC 68-2-27
Humidity10% to 95% relative humidity at30C (86F)
Vibrations3G, 20 sine wave cycles, 5 to 150 Hz, DIN IEC 68-2-6
5G, noise 5 to 1.000 Hz, 30 minutes, DIN IEC 68-2-64
Data
Data Retention> 10 years without power
Write Cycles100,000 writes
Memory Size10,000 Bytes user definable
Identification Code48 bit fixed ID
Configuration
Device227002, 227003, 227004
Ping RateConfigurable from 0.5 to 300 seconds insteps of 0.5 seconds
Number of BurstsConfigurable from 0 to 15
Broadcast User DataUp to 50 Bytes
Electrical
Power SourceLithium Battery (non-replaceable)
Battery MonitoringYes
Standard/Certification
EuropeCE (EN 300 220-1, -3; EN 301 489-1,-3; EN 60950)
North AmericaFCC Part 15 (US); Industry Canada
Physical
Dimensions131 28 21 mm (5.2 1.1 0.85 inches)
EnclosurePlastic (Qinnacryl)
Weight 50 g (1.75 ounces)
Enclosure ratingIP 65